| Specification |
| Model NB-T | 70296/192 | 10396/192 |
| Rated Power | 7000W | 10KW |
| Peak Power(20ms) | 21000W | 30KW |
| Start Motor | 5HP | 7HP |
| Battery Voltage | 96/192VDC | 96/192VDC |
| Size(L*W*Hmm) | 485*300*646 |
| Packing Size(L*W*Hmm) | 550*365*785 |
| N.W.(kg) | 62 | 66 |
| G.W.(kg)(Carton Packing) | 72 | 77 |
| Installation Method | Tower |
| Parameter |
| Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) |
| AC Input Voltage Range | 73VAC~138VAC / 145VAC~275VAC(7000W); 98VAC~125VAC / 195VAC~250VAC(10KW) |
| AC Input Frequency Range | 45Hz~64Hz |
| Max AC charging current | 15A MAX(Depending on the model) |
| AC charging voltage | LEAD battery:Charge Voltage :14V; Float Voltage:13.8V(Single battery voltage) |
| AC charging method | Three-stage (constant current, constant voltage, floating charge) |
| Output | Efficiency(Battery Mode) | ≥85% |
| Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2%(Battery Mode) |
| Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 |
| Output Wave(Battery Mode) | Pure Sine Wave |
| Efficiency(AC Mode) | >99% |
| Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% |
| Output Frequency(AC Mode) | Tracking Automatically |
| Output waveform distortion(Battery Mode) | ≤3%(Linear load) |
| No load loss(Battery Mode) | ≤2.5% rated power(7KW);≤1% rated power(10KW ) |
| No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) |
| No load loss(Energy saving Mode) | ≤10W |
| Battery Type | Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements |
| Protection | Battery undervoltage alarm | 11V(Single battery voltage) |
| Battery undervoltage protection | 10.5V(Single battery voltage) |
| Battery overvoltage alarm | 15V(Single battery voltage) |
| Battery overvoltage protection | 17V(Single battery voltage) |
| Battery overvoltage recovery voltage | 14.5V(Single battery voltage) |
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
| Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
| Temperature protection | >90°C(Shut down output) |
| Alarm | A | Normal working condition, buzzer has no alarm sound |
| B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
| C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
Inside Solar controller | Charging Mode | PWM |
| Charging current | 96V/192V System: 50A,100A |
| PV Input Voltage Range | 96V System:120V-176V; 192V System:240V-352V |
| Max PV Input Voltage(At 25℃) | 96V System:200V; 192V System:400V |
| PV Array Maximum Power | 96V System:5.6KW,11.2KW; 192V System:11.2KW,22.4KW |
| Standby loss | ≤3W |
| Maximum conversion efficiency | >95% |
| Working Mode | Battery First/AC First/Saving Energy Mode |
| Transfer Time | ≤4ms |
| Display | LCD |
| Thermal method | Cooling fan in intelligent control |
| Communication | RS232(Optional) |
| Environment | Operating temperature | -10℃~40℃ |
| Storage temperature | -15℃~60℃ |
| Noise | ≤55dB |
| Elevation | 2000m(More than derating) |
| Humidity | 0%~95% ,No condensation |
| Warranty | 3 years |
| Note: All specifications are subject to change without prior notice |