Application:

Uninterruptible Power Supply(UPS); Emergency Power Supply(EPS);

Emergency Backup Power;               Emergency Light;

Railway System;                                Aircraft Signal System;

Alarm and Security Systems;            Electronic Instruments and Equipment;

Telecom Communication System;     DC Screen Power Supply;

Navigation Mark Signal System;        Solar Wind Energy System.


XD12-12 Battery (12V12Ah)

  • XD12-12 Battery (12V12Ah)
XD12-12 Battery (12V12Ah)
  • 产品介绍
  • 右边简介
  • 产品介绍(手机)

specification
Nominal Voltage12V
Nominal Capacity   (10HR)12.0AH
Battery   sizeLength151±1mm (5.95 inches)
Width98±1mm (3.86 inches)
Height95±1mm (3.74 inches)
Total Height (including terminal)101±1mm (3.98 inches)
Weight 3.5 kg (7.7 lbs)
Terminal   typeT1 / T2
Housing   materialABS
Rated Capacity 12.0 AH/0.60A (20hr ,1.80V/Cell,25℃/77℉)
 11.2 AH/1.12A (10hr,1.80V/Cell,25℃/77℉)
 10.2 AH/2.04A (5hr,1.75V/Cell,25℃/77℉)
 9.2 AH/3.06A (3hr,1.75V/Cell,25℃/77℉)
 7.54AH/7.54A (1hr,1.60V/Cell,25℃/77℉)
Maximum Discharge   Current180A (5s)
Battery Internal   Resistance17mΩ
Operating
    Temperature Range
Discharging-15 ~ 50℃ (5 ~ 122℉)
Charging0 ~ 40℃ (32 ~ 104℉)
Storage-15 ~ 40℃ (5~ 104℉)
Rated   Operating Temperature25±3℃ (77±5℉ )
RecycleAt a   temperature of 25 °C and  a   voltage  of  14.4 V to 15.0 V,  the initial charge current is
     less than 3.6 A.  The correction  factor    is -30mV/°C
Floating   Charge At a   temperature of 25℃ and a voltage of 13.5 V to 13.8 V, the initial charging   current
     is not limited. The correction   factor is -20mV/°C
Capacity affected
      by temperature
40℃(104   ℉)103%
25℃( 77 ℉ )100%
0℃( 32 ℉ )86%
Self-dischargeAt a   temperature of 25℃, the battery can store up to 6 months and then need to be   recharged once.  If the battery is   stored
    at a higher temperature, the storage interval will be shortened

Constant current   discharge meter at 25 °C (77 °F)( Amperes)

Voltage
               Time
5 minutes10 minutes15 minutes20 minutes30 minutes45 minutes1 hour2 hours3 hours4 hours5 hours6 hours8 hours10 hours20 hours
1.85V/Cell22.917.514.512.69.727.166.033.572.792.271.851.611.31.080.594
1.80V/Cell30.722.417.614.911.58.336.763.93.002.421.991.721.371.120.60
1.75V/Cell34.624.619.216.011.98.647.074.043.062.482.041.771.41.150.606
1.70V/Cell38.126.920.516.812.48.997.294.143.152.542.091.811.421.170.617
1.65V/Cell42.029.021.817.813.19.217.464.23.282.632.151.851.441.190.625
1.60V/Cell46.331.523.319.013.89.67.544.383.382.712.221.891.451.210.629