Telephone / WhatsApp:
+86 18924874907

Hybrid Solar Inverter Charger Manufacturer
16-year experience  ○Factory wholesale  ○OEM/ODM

Welcome to the website of Guangdong Xindun Power Technology Co.,Ltd.

中文English

PRODUCTS

Guangdong Xindun Power Technology Co.,Ltd.
Tel./Whatsapp/Wechat: +86 18924874907
E-mail: sales@gdxindun.com

Add: 3/F,Bldg.3,area C,European Industry Park,Chancheng Dist,Foshan,Guangdong,China

Details
Position: Home> Details

Purchasing Hotline+86 18924874907

Share:

Application:

Uninterruptible Power Supply(UPS); Emergency Power Supply(EPS);

Emergency Backup Power;               Emergency Light;

Railway System;                                Aircraft Signal System;

Alarm and Security Systems;            Electronic Instruments and Equipment;

Telecom Communication System;     DC Screen Power Supply;

Navigation Mark Signal System;        Solar Wind Energy System.


XD24-12 Battery (12V24Ah)

  • XD24-12 Battery (12V24Ah)
XD24-12 Battery (12V24Ah)
  • 产品介绍
  • 右边简介
  • 产品介绍(手机)

Specification
Nominal Voltage12V
Nominal Capacity   (10HR)24.0AH
Battery   sizeLength165±1mm (6.50 inches)
Width125±1mm (4.92 inches)
Height175±1mm (6.89 inches)
Total Height (including terminal)175±1mm (6.89 inches)
Weight7.5 kg (17.4 lbs)
Terminal   typeT6 / T12
Housing   materialABS
Rated Capacity24.0 AH/1.20A (20hr   ,1.80V/Cell,25℃/77℉)
22.3   AH/2.23A (10hr,1.80V/Cell,25℃/77℉)
20.4   AH/4.08A (5hr,1.75V/Cell,25℃/77℉)
18.4   AH/6.12A (3hr,1.75V/Cell,25℃/77℉)
15.1   AH/15.1A (1hr,1.60V/Cell,25℃/77℉)
Maximum Discharge   Current360A (5s)
Battery Internal   Resistance15mΩ
Operating
    Temperature Range
Discharging-15 ~ 50℃ (5 ~ 122℉)
Charging0 ~ 40℃ (32 ~ 104℉)
Storage-15 ~ 40℃ (5~ 104℉)
Rated   Operating Temperature25±3℃ (77±5℉ )
RecycleAt a   temperature of 25 °C and  a   voltage  of  14.4 V to 15.0 V,  the initial charge current is
     less than 7.2 A.  The correction  factor    is -30mV/°C
Floating   Charge At a   temperature of 25℃ and a voltage of 13.5 V to 13.8 V, the initial charging   current
     is not limited. The correction   factor is -20mV/°C
Capacity affected
      by temperature
40℃(104   ℉)103%
25℃( 77 ℉ )100%
0℃( 32 ℉ )86%
Self-dischargeAt a   temperature of 25℃, the battery can store up to 6 months and then need to be   recharged once.  If the battery is   stored
    at a higher temperature, the storage interval will be shortened

Constant current   discharge meter at 25 °C (77 °F)( Amperes)

Voltage
               Time
5 minutes10 minutes15 minutes20 minutes30 minutes45 minutes1 hour2 hours3 hours4 hours5 hours6 hours8 hours10 hours20 hours
1.85V/Cell45.735.129.125.119.414.3212.077.145.584.543.73.212.592.161.19
1.80V/Cell61.344.835.129.722.916.713.527.796.014.853.973.452.752.231.2
1.75V/Cell69.249.338.432.023.817.314.148.086.124.964.083.542.82.291.21
1.70V/Cell76.253.741.033.624.818.014.598.286.295.094.183.612.842.341.23
1.65V/Cell84.058.043.635.726.118.414.938.406.565.264.33.692.882.391.25
1.60V/Cell92.662.946.638.027.619.215.078.766.765.434.443.772.912.411.26


Previous
Next

Recommend

Purchasing

* Tel/Whatsapp:
* E-mail:
* Purchase Intention:
Submit